Titration errors: trace the cause and direction
Key idea: Trace a titration error through sample amount, titrant concentration and recorded volume before predicting its effect. Concordant repeats can still share the same dilution or end-point bias.
Offline pages
Saved on this device only. Connect at least once every 30 days to confirm Premium. Sign-out or a change of account removes saved copies.
Loading guide controls…
Guided lessons · coming soon
Guided lesson
Guided steps
- Follow the titre through the acid concentration calculation.
- Explain why the recorded volume is too high.
- Account for the liquid used to fill the tip.
- Explain overshoot and how to prevent it.
- Compare dilution before and after delivering the aliquot.
- Predict the titre and calculated acid concentration.
- Trace water in the burette through the calculation.
- Calculate both acid concentrations and the percentage error.
- Explain whether more repeats would remove the error.
On this page
You stopped at:
ContinueA titre can be repeatable and still be wrong. To explain an error, follow what changes: the amount in the sample aliquot, the titrant concentration, or the volume recorded by the burette. Then follow that change through the calculation.
If readings and concordance are unfamiliar, start with titration technique.
Trace the error before naming its direction
For an acid aliquot titrated with alkali of known concentration, the calculation uses the recorded alkali volume to find its amount, applies the reaction ratio, then divides by the acid aliquot volume.
Ask three questions:
- Did the error change the actual amount of acid in the pipetted aliquot?
- Did it change the actual concentration of the alkali delivered?
- Does the recorded volume equal the volume that reached the flask?
State the known and unknown solutions before predicting a calculated concentration. A high titre alone cannot show the direction for every possible analysis.
Where did the recorded liquid go?
Guided practice 1
Trace the effect of an air bubble in the burette tip
Problem
Try this before viewing the solution
Hints
Hint 1
follow the liquid
Compare liquid leaving the reservoir with liquid reaching the flask.Hint 2
compare volumes
The reading change includes both tip filling and flask delivery.Show solution step by step
Account for tip filling
Method
State that some titrant displaces the air and fills the jet.Reason
That portion changes the burette reading but does not reach the flask.Working
Answer
V_reading = Vₜᵢₚ + V_flask.Give the direction
Method
Conclude that the recorded titre is too high.Reason
The indicated volume is larger than the volume that actually reacted in the flask.Working
Answer
Improvement: run titrant through the jet and remove bubbles before the initial reading.
Quick check
Check your understanding 1 Check the bubble’s liquid account
A bubble is present in the burette tip at the initial reading and clears during titration. Check where some of the indicated liquid goes first and how that affects the recorded titre.
Show answer
Fills the burette tip; Too high. The burette change includes liquid used to fill the tip, so it exceeds the volume delivered to the flask.
If a bubble remains unchanged throughout the titration, it does not consume the extra volume described above. The high-titre explanation requires the tip to fill after the initial reading.
Has the endpoint been passed?
Exam-style question 1
Evaluate endpoint overshoot
Examination question
Try this before viewing the solution
Show solution step by step
Identify overshoot
1 markMethod
State that excess titrant is delivered after the endpoint is reached.Reason
Rapid addition does not allow the first permanent colour change to be judged promptly.Working
Answer
Delivered volume exceeds the volume needed for the chosen endpoint.Give the direction
1 markMethod
State that the recorded titre is too high.Reason
The final burette reading includes excess titrant.Working
Answer
V_recorded > V_endpoint.Prevent the error
1 markMethod
Add titrant dropwise with swirling near the endpoint and use a white tile to see the first permanent change.Reason
Small additions and better contrast reduce the chance of passing the endpoint.Working
Answer
Dropwise + swirl + first permanent colour change.
Self-mark with the mark scheme
Tick each mark point that your answer includes.
Self-mark the excess addition, high direction and matched prevention.
Water in a pipette or water in the flask?
The pipette fixes the sample aliquot. Water mixed with the sample before that aliquot is delivered reduces its concentration. A small deionised-water wash after the aliquot is in the conical flask changes the total volume but leaves the sample amount unchanged. Use enough water to wash splashes down, while keeping the specified endpoint detectable.
Try it yourself 2
Trace water left in a pipette
Problem
A pipette contains residual deionised water before it is filled to the mark with an acid sample. The acid is titrated with alkali of known concentration. Predict the effect on the mean titre and on the calculated acid concentration.
Try this before viewing the solution
Hints
Hint 1
locate dilution
Water in the pipette mixes with the acid before the aliquot is delivered.
Hint 2
follow moles
Fewer acid moles require fewer alkali moles at equivalence.
Show solution step by step
Trace the aliquot
Method
State that residual water dilutes the acid inside the pipette, so the delivered aliquot contains fewer acid moles.
Reason
The pipette still delivers its nominal total volume, but not the intended acid concentration.
Working
Answer
n(acid in aliquot) is too low.Predict the titre
Method
Conclude that less alkali is required and the mean titre is too low.
Reason
Equivalence moles follow the reaction ratio.Working
Answer
V(alkali) is too low.Predict the reported concentration
Method
Conclude that the calculated concentration of the original acid is too low.
Reason
The calculation assigns the underestimated moles to the nominal pipette volume.
Working
Answer
Rinse the pipette with the acid sample before transfer.
Quick check
Water in the conical flask leaves aliquot moles unchanged; water in the pipette dilutes the aliquot before its moles are fixed.
Water left in the burette
Check your understanding 2 Trace dilution of the titrant
A burette should contain 0.100 mol dm⁻³ sodium hydroxide. A student leaves deionised water in it, then fills it with this solution. Assume the water mixes with the titrant. The titration is used to find the concentration of a fixed acid aliquot. Explain the effect on the titre and the reported acid concentration.
Show hint
Compare the actual alkali concentration with the concentration used in the calculation.
Show answer
The actual alkali concentration is lower. The unchanged acid amount therefore needs a larger alkali volume at equivalence. Using 0.100 mol dm⁻³ with this larger volume overestimates the alkali amount, and hence the acid amount and concentration. Rinse the burette with the titrant and fill the jet before starting.
Check your understanding 3 Can close agreement hide a concentration error?
A 25.0 cm³ aliquot of a monoprotic acid reacts 1:1 with sodium hydroxide. Concordant titres give a mean of 20.0 cm³. The student assumes the alkali is 0.100 mol dm⁻³, but its actual concentration is 0.0800 mol dm⁻³. Calculate the reported and actual acid concentrations, then the percentage error relative to the actual value.
Show hint
Perform the same calculation twice, changing only the alkali concentration. Use the actual acid concentration as the denominator of the percentage error.
Show the steps Optional working
Show the steps Optional working
Show the steps Optional working
Show answer
The reported concentration is:
Using the actual alkali concentration gives:
Check your understanding 4 Would more repeats remove this error?
In the acid analysis above, the assumed sodium hydroxide concentration is 0.100 mol dm⁻³ but the actual value is 0.0800 mol dm⁻³. Explain whether repeating with that same alkali removes the error and how you would address it.
Show answer
The reported concentration is:
Using the actual alkali concentration gives:
Repeating with the same incorrectly assumed concentration repeats the bias. Close agreement checks repeatability; it cannot verify the titrant concentration. Check that concentration with a suitable standard before reporting the result.
A useful evaluation connects cause → changed quantity → direction → matched improvement. “Repeat more often” can reduce random variation in a mean, but it cannot replace missing solute, correct dilution or undo a consistent overshoot.
Spotted an error? Report a correction
Syllabus and review details
- GCE A-Level H2 Chemistry 2027 · 9476-2027
9476 (2027), complete syllabus
Last reviewed: